PA12 Flame retardant HG-PA12-FR001
Product Description:
PA12 flame retardant injection moulding grade. Natural colour.
Suitable for parts requiring flame retardancy. Rated V-0 at 0.4 mm according to UL-94.
Product Description:
PA12 flame retardant injection moulding grade. Natural colour.
Suitable for parts requiring flame retardancy. Rated V-0 at 0.4 mm according to UL-94.
Brand Name: | HENGA | |||
Color: | NATURE | |||
Model Number: | HG-PA12-FR001 | |||
Certificates: | REACH, ROHS, TS16949 | |||
Features | Flame retardant RoHS Compliant Heat Resistant Heat Stabilizer |
|||
Application | Electrical/Electronic Applications Automotive Hose/Tubing Wire & Cable |
|||
Delivery time: | 3-5days | |||
Physical | Dry | Conditioned | Unit | Test Method |
Density | 1.05 | -- | g/cm³ | ISO 1183 |
Molding Shrinkage | ISO 294-4 | |||
Across Flow | 0.8 | -- | % | |
Flow | 0.6 | -- | % | |
Water Absorption | ISO 62 | |||
Saturation, 23°C | 1.4 | -- | % | |
Equilibrium, 23°C, 50% RH | 0.7 | -- | % | |
Hardness | Dry | Conditioned | Unit | Test Method |
Shore Hardness (Shore D, 15 sec) | -- | 72 | ISO 868 | |
Mechanical | Dry | Conditioned | Unit | Test Method |
Tensile Modulus | 1900 | 1500 | MPa | ISO 527-2 |
Tensile Stress | ISO 527-2 | |||
Yield | 50 | 40 | MPa | |
Break | 40 | 35 | MPa | |
Tensile Strain (Yield) | 5 | 10 | % | ISO 527-2 |
Nominal Tensile Strain at Break | > 50 | > 50 | % | ISO 527-2 |
Impact | Dry | Conditioned | Unit | Test Method |
Charpy Notched Impact Strength | ISO 179/1eA | |||
-30°C | 6 | 6 | kJ/m² | |
23°C | 5 | 7 | kJ/m² | |
Charpy Unnotched Impact Strength | ISO 179/1eU | |||
-30°C | No Break | No Break | ||
23°C | No Break | No Break | ||
Thermal | Dry | Conditioned | Unit | Test Method |
Heat Deflection Temperature | ||||
0.45 MPa, Unannealed | 130 | -- | °C | ISO 75-2/B |
1.8 MPa, Unannealed | 50 | -- | °C | ISO 75-2/A |
Continuous Use Temperature | ||||
-- 3 | 90.0 to 110 | -- | °C | ISO 2578 |
-- 4 | 150 | -- | °C | Internal Method |
Melting Temperature 5 | 178 | -- | °C | ISO 11357-3 |
CLTE | ISO 11359-2 | |||
Flow | 9.00E-05 | -- | cm/cm/°C | |
Transverse | 1.20E-04 | -- | cm/cm/°C | |
Electrical | Dry | Conditioned | Unit | Test Method |
Surface Resistivity | -- | 1.00E+12 | ohms | IEC 60093 |
Volume Resistivity | -- | 1.00E+14 | ohms·cm | IEC 60093 |
Electric Strength | -- | 34 | kV/mm | IEC 60243-1 |
Comparative Tracking Index | -- | 600 | V | IEC 60112 |
Flammability | Dry | Conditioned | Unit | Test Method |
Flammability Classification (0.8 mm) | V-2 | -- | IEC 60695-11-10, -20 | |
Additional Information | Dry | Conditioned | Test Method | |
ISO Type | PA12, MHF, 18-010 | -- | ISO 1874 |