Product Description:
Medium viscosity, 30 % glass fibres reinforced standard injection moulding grade with very good mechanical properties 

Application
PBT with glass fiber is applied for Automobile / mechanical equipment/ precision instrument parts and electronic appliances.
 




Minimum order quantity

1


Brand Name: HENGA    
Color: NATURE    
Model Number: HG-PBT-GF001    
Certificates: REACH, ROHS, TS16949    
Usage: Automobile    
mechanical equipment
precision instrument parts
electronic appliances
Delivery time: 3-5days    
Physical Nominal Value Unit Test Method
Density 1.53 g/cm³ ISO 1183
Water Absorption     ISO 62
Saturation, 23°C 0.37 %  
Equilibrium, 23°C, 50% RH 0.13 %  
Mechanical Nominal Value Unit Test Method
Tensile Modulus 2 (23°C) 10000 MPa ISO 527-2
Tensile Stress 2 (Break, 23°C) 140 MPa ISO 527-2/5
Tensile Strain 2 (Break, 23°C) 2.6 % ISO 527-2/5
Flexural Stress 3 (23°C) 210 MPa ISO 178
Impact Nominal Value Unit Test Method
Charpy Notched Impact Strength 3     ISO 179/1eA
-30°C 10 kJ/m²  
23°C 11 kJ/m²  
Charpy Unnotched Impact Strength 3      
23°C 60 kJ/m² ISO 179/1eU
23°C 55 kJ/m² ISO 179/2eU
Notched Izod Impact Strength 3     ISO 180/1A
-30°C 9 kJ/m²  
23°C 10 kJ/m²  
Thermal Nominal Value Unit Test Method
Heat Deflection Temperature 4      
0.45 MPa, Unannealed 220 °C ISO 75-2/B
1.8 MPa, Unannealed 205 °C ISO 75-2/A
Melting Temperature (DSC) 5 223 °C ISO 3146
CLTE 6     DIN 53752
Flow 3.50E-05 cm/cm/°C  
Transverse 9.50E-05 cm/cm/°C  
Maximum Service Temperature     IEC 216
20000 hrs 140    
some hours 170 °C  
Electrical Nominal Value Unit Test Method
Surface Resistivity 7 > 1.0E+14 ohms IEC 60093
Volume Resistivity 7 > 1.0E+16 ohms·cm IEC 60093
Electric Strength 29 kV/mm IEC 60243-1
Relative Permittivity 7 (1 MHz) 4.1   IEC 60250
Dissipation Factor 7 (1 MHz) 0.02   IEC 60250
Comparative Tracking Index 450 V IEC 60112
Flammability Nominal Value Unit Test Method
Flame Rating     UL 94
0.8 mm 8 HB    
1.6 mm 9 HB    
Injection Nominal Value Unit  
Drying Temperature 110 to 130 °C  
Drying Time 2.0 to 4.0 hr  
Processing (Melt) Temp 245 to 265 °C  
Mold Temperature 60 to 100 °C  